View all our industries

Our industries

Time to calibrate?

Secure your quality and reduce defects through Tool Calibration and Accredited Quality Assurance Calibration.​
power tool calibration, tool testing, metrology, machine capability test

Momentum Talks

Discover inspirational and engaging talks on Atlas Copco
Momentum Talks
Close

Learn about silencing mechanisms for vane air motors

The noise generated by an air motor is mainly caused by the exhaust air exiting the motor. The noise level increases with speed and is greatest at free speed.

Illustrations of air motor silencing methods
All Atlas Copco motors are supplied with a threaded exhaust port permitting a screw-in silencer to be fitted to reduce noise level. By fitting a hose between the exhaust port and the silencer the noise level can be reduced even further. The effect of employing the various silencing techniques is indicated in the illustration and table below. Note that a silencer may cause power losses if incorrectly sized.
Example of: 0.36 kW motor No-load speed Anechoic room Interval of 1 minute
Illustration no. Measure Noise level
dB (a)
1 None 94
2 Silencer only 77
3 Hose only 84
4 Hose with silencer 75
Take a look at our product range
Take a look at our product range
 
Find out about air motors' applications
Find out about air motors' applications
 
Download library for more resources
Download library for more resources
 
Contact us!
Contact us!
 
Scroll up