How to earn thousands of rupees from the compressed air in your plant.
Do you want to earn thousands of rupees from compressed air then you may welcome our guidelines to do No Load test at your plant which help in realizing potential at your plant
There are certain things in the life which gives you sense of fulfillment specially those which are done by yourself. We place a much stronger belief in the data and reports, which are created either by us or some trusted source. But the sense of fulfillment that we get from own findings is extremely satisfying.
One of the activities in the manufacturing plant that can be done by yourself is air leakages detection. These compressed air leakages are generally observed in the compressed air system and industry experts classify the leakages into two categories - planned leakages and unplanned leakages.
The planned leakages by design of the compressed air system e.g. blowing, drying, purging, etc. On the other hand, the unplanned leaks are due to maintenance & operating issues of the plant.
As per study, the compressed air leakages in the plant can lead to approximate 10 - 30% of the compressed air energy and thus result in huge power losses coupled with operating losses.
The air leakages also lead to other issues in the plant like pressure drop, moisture in compressed air application and bad air quality, therefore reducing the overall efficiency of the entire system including performance of the air compressor and compressed air dryer.
So, it is highly recommended that leaks should be quantified and accordingly arrested. This can only be done with proper measuring techniques as if you cannot measure it, you cannot improve it.
The most common practices in industry to reduce the leakages are:
No load Test for leak quantification
Leak Identification through ultrasonic leak detector
Out of these two, no load test can be done easily at plant itself without much investment. However, this test requires plant shutdown, so that compressor running during no production can be evaluated for total leaks available across network.
Atlas Copco Energy Experts guide you on how you can do “No load test” and quantify leakages and thus can evaluate the possibility of
Up to 10% energy bill reduction
Up to 5% reduction in pressure set point
Up to 25% reduction in unload hours of the compressors.
Steps to conduct No Load Test at the plant
Pre-requisites:
Ensure selected compressor should be properly maintained without any physical abnormality.
Ensure all your applications are off and there should not be any use of compressed air.
Ensure test will be conducted at same pressure band at which plant is operated.
Steps to follow:
This test should be conducted during a shutdown period.
All the application valves should be closed.
Run the desired compressor. In case of multiple installation with different power ratings, select any compressor.
Let the compressor stabilize by loading and unloading.
Note down the load and unload timings and collect 5 samples for the average.
Now enter the readings in the below formula.
Leakage (QL) = { T/( T + t )} X QR
where,
T = Load time (seconds)
t = Unload time (seconds)
QR = Rated compressor capacity which is used for leak test
QL = Leakage calculated
Illustrative Example
Let’s assume there are four compressors in the plant with following flow rating in cfm
100 cfm (running compressor)
100 cfm (stand-by compressor)
75 cfm (running compressor)
60 cfm (stand-by compressor)
Now, select 75 cfm compressor for no load test and follow the above mentioned 6 steps to record the load and unload time. Assuming average time calculated after 5 samples as:
Avg load time : 25 seconds
Avg unload time: 45 seconds
Enter the data in the above formula; Leakage (QL) = { T/( T + t )} X QR
i.e. Leakage (QL) = {25 /( 25+45)} X 75 = 26 cfm (Potential compressed air leakages)
As a thumb rule, screw compressors consume 1 kW energy to genrate 6 cfm of the compressed air.
So, your 26 cfm = approx 4.3 kW = approx216000 INR/ Year**
**Assuming 6000 running hours annually and average Energy cost is INR 8 per unit.
You may also convert the potential leakages into leakages percentage as:
Leakage % = Leakage result/ Total running capacity
So, for our example, leakage % = 26/ 175 = 14.8% of total runnig capacity.
Conclusion
The above example gives you an idea of percentage leakages in your plant as well as a potential energy-saving through leak repair. Our energy managers recommend the leakage percent should always be less than 5% so that you can run your plant at optimum energy levels.
Did you know our service team already helped more than 60 customers to realize a potential saving of around 1500kW during April-May 2020 (approx. 63M INR in energy costs).
Recently, our energy managers have conducted a webinar on energy-saving solutions in the compressed air system and explained this topic in detail. You may watch the recording of this webinar here.
Until the last decade, low pressure blowers used lobe or roots compression technology to produce air for use in a variety of industries. However, the screw blower is becoming the preferable option due to its efficiency benefits - particularly in...
There are 2 ways of pneumatic conveying. One is called dilute phase, which requires pressure levels up to 0.3-2.5 bar(g). This is used for materials with a low bulk density. The other type is called dense phase. This needs pressure levels of 1.5-4...
Nitrogen navigators: Steering safety & precision in blanketing operations
12 August, 2024
In the realm of industrial safety and efficiency, the concept of blanketing emerges as a pivotal strategy. Predominantly utilized in sectors dealing with volatile or sensitive substances, blanketing refers to the practice of overlaying a protective...